Unlike other imaging options, MRI displays details of tissue such as tendons, nerves, muscle, and organs. All rights reserved. Skip to main content News Careers Investors Region selector Argentina Brazil Chile China Colombia Deutschland Espanol Europe India Japan 2023 Boston Medical Center. Boston Scientific is dedicated to transforming lives through innovative medical solutions that improve the health of patients around the world. Unlike other imaging options, MRI displays details of tissue such as tendons, nerves, muscle, and organs. A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed ureter (e.g., from stone, stricture, compression, fibrosis, trauma) to maintain luminal patency allowing urine to drain from the renal pelvis to the bladder. Find out who we are, explore careers at the company, and view our financial performance. Allergic/anaphylactic reaction; Amputation; Aneurysm; Arteriovenous fistula; Death related/unrelated to procedure; Dissection; Embolization; Extravasation; Fever; Hemorrhage/bleeding requiring a blood transfusion; Hematoma; Hypotension/hypertension; Incorrect positioning of the stent requiring further stenting or surgery; Intimal injury/dissection; Ischemia/infarction of tissue/organ; Local infection; Malposition (failure to deliver the stent to the intended site); Open surgical repair; Pain; Pulmonary embolism; Pseudoaneurysm; Renal failure; Respiratory arrest; Restenosis; Rupture; Septicemia/bacteremia; Stent Fracture; Stent Migration; Vasospasm; Venous occlusion/thrombosis/restenosis. See all healthcare professional information, Bladder leakage and pelvic organ prolapse, Enteral feeding tube and esophageal stent device support, Cardiac Resynchronization Therapy (CRT) device support, Peripheral Artery and Vein interventions device support, Transcatheter Aortic Valve Replacement device support, Spinal Cord Stimulator (SCS) systems device support, EMERGE PTCA Dilatation Catheter - Boston Scientific, EDUCARE Medical Education and Training Courses, Patients and Caregivers - Support and Resources, Do not sell or share my personal information, Exceptional deliverability and low profiles designed to cross tight lesions, High rated burst pressure 18 ATM (1824 kPa) for sizing flexibility, Two shaft designs provide options for challenging lesions, EMERGE Catheter is designed for exceptional simultaneous use performance, Shaft profile allows for simultaneous use of two Monorail catheters in a 6 F guide catheter and two Over-the-Wire catheters in an 8 F guide catheter*, Designed to optimize stent apposition in large, proximal vessels, Two shaft options with distinct technologies designed to provide flexibility for navigating to and through even the most challenging lesions, Push technology: Single-segment inner shaft design for ultimate pushability 1.2 mm and 1.5 mm Push, Workhorse technology: Bi-Segment inner shaft designed for maximum deliverability without sacrificing pushability (1.2 mm to 4.0 mm). Kaplan-Meier Primary Patency in Post-Thrombotic Lesions at 36 months, Kaplan-Meier Primary Patency in Non-Thrombotic Lesions at 36 months, Freedom from Target Lesion Revascularization (TLR) at 36 months. The balloon catheter should be used only by physicians trained in the performance of percutaneous transluminal coronary angioplasty. Do not attempt to break, damage, or disrupt the stent after placement. outflow obstruction. 2792 0 obj
<>/Filter/FlateDecode/ID[<8422C93A02CE4B499E7EC15CE70ACD24>]/Index[2785 21]/Info 2784 0 R/Length 60/Prev 713660/Root 2786 0 R/Size 2806/Type/XRef/W[1 3 1]>>stream
%%EOF
Safety Topic / Subject PMT Halo System with Carbon Graphite Open Back Ring and Titanium Skull Pins PMT Corporation Chanhassen, M. 3: . The technologist will then remove the IV, if applicable, and bring the patient out of the room to change back into their clothes. All rights reserved. BioLinx is a blend of the Medtronic proprietary components C10 and C19, and PVP Do not expose the delivery system to organic solvents, e.g., alcohol. Reproduced with Permission from the GMDN Agency. Safe MR imaging involves a careful initial patient screening, accurate determination of the permanent implanted or temporary cardiovascular device and its properties, a thoughtful analysis of the risks and benefits of performing the examination at that time, and, when indicated, appropriate physician management and supervision. For both in-person and virtual visits, BMC is here to ensure you have everything you need to make your visit a success. One Boston Medical Center Place ** On all models 3.25 mm x 20 mm and 30 mm length balloons 2.75 mm. Please consult Instructions for Use for product indications for use, contraindications, warnings, precautions, potential complications, adverse events and detailed safety information. Data on file. Find the information you need, whether you've been diagnosed with a health condition, have an implanted device, or need support. The technologist performing the exam will monitor the patient throughout the scan and they are also able to talk with each other the entire time. Coils, Filters, Stents, and Grafts More. Across all sizes, foreshortening ranged from -4% to 10%, with a mean of 2.9% (values based on mathematical calculations). Several of these demonstrated magnetic field interactions. The C-Code used for EMERGE PTCA Dilatation Catheter is C1725 Catheter, Transluminal, Angioplasty, Non-Laser (may include guidance, infusion/perfusion capability). 1.5 . Testing completed by Boston Scientific Corporation. Do not use the device after the Use By date specified on the label. If excessive force is felt during stent deployment, do not force the delivery system. Three-Year Results from the Venovo Venous Stent Study for the Treatment of Iliac and Femoral Vein Obstruction. Cardiovasc Intervent Radiol, vol. Balloon catheter retrieval methods (use of additional wires, snares, and/or forceps) may result in trauma to the treated vessel and/or the vascular access site. A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed ureter (e.g., from stone, stricture, compression, fibrosis, trauma) to maintain luminal patency allowing urine to drain from the renal pelvis to the bladder. 3Foreshortening is calculated as the difference, represented as percentage, between the compressed stent length and expanded stent length at minimum/maximum oversize (1-3 mm). The VERNACULAR study results provide scientific evidence that the Venovo Venous Stent System is safe and effective for the treatment of symptomatic iliofemoral venous
The ordering physician will go over the findings with their patient. 2023 Boston Scientific Corporation or its affiliates. Before withdrawing the balloon catheter, visually confirm complete balloon deflation by fluoroscopy. Complications can include but are not limited to bleeding, hematoma, or pseudoaneurysm. Find products, medical specialty information, and education opportunities. alcohol or nitroglycerine, stem cells, etc.) The device is typically intended for long-term, but not permanent, implantation. Boston Medical Center has a long tradition of providing accessible and exceptional care for everyone who comes through our doors. 850 W Rio Salado Pkwy, Tempe, AZ 85281 United States, 6:00 a.m. 4:30 p.m. Arizona Time (Monday-Friday), Surgical Instruments and Sterilization Container products. The long-term outcomes following repeat dilatation of endothelialized stents are unknown. In addition to this commitment, our robust research and teaching programs keep our hospital on the cutting-edge, while pushing medical care into the future. Secondary endpoints included acute technical success, Quality of Life (QoL) assessment, Venous Clinical Severity Score (VCSS Pain score) and stent fractures. 5.7 MAGNETIC RESONANCE IMAGING (MRI) SAFETY INFORMATION . BD supports the healthcare industry with market-leading products and services that aim to improve care while lowering costs. 44, no. GMDN Names and Definitions: Copyright GMDN Agency 2015. 2805 0 obj
<>stream
Stenting across a major branch could cause difficulties during future diagnostic or therapeutic procedures. Changing Clinical Practice: Venous Experts Discuss the VenovoVenous Stent. An anteroposterior and lateral x-ray for each evaluated stent were sent to an independent core lab for analysis. Note: Bench testing was conducted with NC Emerge OTW and NC Emerge MR PTCA Dilatation Catheters and marketed Boston Scientific balloon expandable stents. hbbd```b``>"tH/ We are committed to providing the best experience possible for our patients and visitors. EMERGE is a predilatation balloon catheter designed to navigate and cross even the most challenging lesions with ease. Dr. Gerard O'Sullivan, FSIR, FEBIR of Galway University Hospitals in Galway, Ireland and Dr. Steven Dubenec, MBBS, FRACS, Head of Vascular Surgery at the Royal Prince Alfred Hospital in Sydney, Australia discuss important features of the VenovoVenous Stent and their personal experiences using the product. Missing x-ray analyses were recorded as protocol deviations. All rights reserved. People scheduled for an MRI should expect to be at BMC for about 1-1.5 hours. Recorded at the London Charing Cross Symposium in 2019. Directions for Use. The C-Code used forNC EMERGE PTCA Dilatation Catheter is C1725 Catheter, Transluminal, Angioplasty, Non-Laser (may include guidance, infusion/perfusion capability). Remove the delivery system and replace with a new unit. The safety and effectiveness of this PTCA balloon catheter for the treatment of in-stent restenosis (ISR) has not been established. Patients must remain still and quiet for the entire exam, as any movement, even speaking, can make the images blurry. GMDN Names and Definitions: Copyright GMDN Agency 2015. Stents were evaluated at the 36-month follow-up for fracture analysis. The NC Emerge OTW and NC Emerge MR PTCA Dilatation Catheters (balloon models 2.00- 5.00 mm) are also indicated for the post-delivery expansion of balloon expandable stents (bare metal and drug-eluting). PMA Applicant: Boston Scientific Corporation Address: One Scimed Place, Maple Grove, MN 55311-1566 Approval Date: August 11, 2020 Approval Letter: Approval Order What is it? BD offers training resources to help improve your clinical practices as part of our goal of advancing the world of health. Catalog Number: Company Name: BOSTON SCIENTIFIC CORPORATION Primary DI Number: 08714729861720 Issuing Agency: GS1 Commercial Distribution End Date: Device Count: 1 Labeler D-U-N-S Number*: 021717889 * Terms of Use Device Description: Ureteral Stent CLOSE Device Characteristics Device Record Status Alternative and Additional Identifiers With exceptional deliverability, an ultra-low tip profile, and unparalleled expansion range, it offers complete support for vessels of any size and complexity. 2023 Boston Scientific Corporation or its affiliates. Boston Scientific, www.bostonscientific.com . *On all models 3.25 mm x 20 mm and 30 mm length balloons 2.75 mm. U~ S?)DO(X`dpHpEjq[p10Lv1 Hjer8(,mArFFzMfzSdZn8,=}SGp=!x2|6eCjoVJfPb*K=]Q
b?s/=2>I*6yeO-+7Xb{C/^9)#/> # Tu[sS*[eWc!Z9PEPW-OG#*vQJ*U'
lK(^>EZoCq8VlS6>s$i \s#zG=?O4E
Wallstent EndoprosthesisMagic Wallstent3.5 x 25coil, stent, filterSchneider (USA) Inc.Pfizer Medical Technology GroupMinneapolis, M, Wallstent EndoprosthesisWith Permalume covering8 x 80coil, stent, filterSchneider (USA) Inc.Minneapolis, M, Wallstent Esophageal II Endoprosthesis20 x 130coil, stent, filterSchneider (USA) Inc.Pfizer Medical Technology GroupMinneapolis, M, WALLSTENT RX Biliary EndoprosthesisBoston Scientifichttp://www.bostonscientific.com, WALLSTENT Venous, Single and Overlapping Stents up to 120-mm Boston Scientific www.bostonscientific.com, WallStentcarotid artery stentBoston Scientific CorporationMaple Grove, MN, Wallstentplatinum and cobalt-alloycoil, stent, filterSchneiderBulach, Switzerland, Walvekar Salivary Duct StentHood Laboratories, www.hoodlabs.com, Watchman Gen 4 ImplantAtritech Inc. and Boston Scientific, www.bostonscientific.com, Watchman Left Atrial Appendage Closure DeviceAtritech Inc. and Boston Scientific, www.bostonscientific.com, WEB Aneurysm Embolization Device Sequent Medical, Inc./Microvention, www.microvention.com, Weck Horizon, Titanium Clip, All sizes Teleflex Medical, www.teleflex.com, WedgeLoc Suture Anchor with Opti-Fiber SuturesMedShape SolutionsAtlanta, GA, WedgeLoc Suture AnchorMedShape Solutions, Inc.Atlanta, GA, Wehrs Incus Prosthesis, Otologic ImplantGyrus ACMI, www.gyrusacmi.com, WessexAortic, Model WAV10heart valveSorin BiomedicaItaly, WessexMitral, Model WMV20heart valveSorin BiomedicaItaly, Westaby T-Y StentHood Laboratories, www.hoodlabs.com, Western EZ-OX Plus SystemALQ-2342 on an Aluminum D cylinderWestern EnterprisesWestlake, OH. Once the scan is complete, the technologist will review the images to make sure all the information needed is there. Premarket Submission Number Not Available/Not Released. We use cookies and other tools to enhance your experience on our website and to analyze our web traffic. Do not use the device with contralateral access. Several of these demonstrated magnetic field interactions. Shellock R & D Services, Inc. email: Frank.ShellockREMOVE@MRIsafety.com. BD promotes clinical excellence by providing various resources on best practices, clinical innovations and industry trends in healthcare. Disposable devices intended to assist implantation may be included. If difficulty is experienced during balloon inflation, do not continue; remove the catheter. The primary effectiveness endpoint of the study was primary patency (PP) at 12 months post-index procedure, defined as: freedom from TVR and freedom from thrombus occlusion and stenosis > 50% as measured by DUS. ESG (Environmental, Social, and Governance), Policies, Guidelines and Statements Center, Venous disease is complex, your stent choice doesn't have to be, Our live chat is available between the hours of 8.30am - 5.00pm EST, Monday - Friday, BD Original Equipment Manufacturing (OEM), Patient Care Support Across the Continuum, Engineered to provide the optimal balance between radial force, flexibility, and compression resistance, Tri-axial delivery system designed to provide accurate deployment to help facilitate optimal stent placement and lesion coverage, 3mm flared stent ends designed to reduce the risk of stent migration and maximize wall apposition. See all healthcare professional information, Bladder leakage and pelvic organ prolapse, Enteral feeding tube and esophageal stent device support, Cardiac Resynchronization Therapy (CRT) device support, Peripheral Artery and Vein interventions device support, Transcatheter Aortic Valve Replacement device support, Spinal Cord Stimulator (SCS) systems device support, EDUCARE Medical Education and Training Courses, Patients and Caregivers - Support and Resources, Do not sell or share my personal information.